Search results for " injection"
showing 10 items of 472 documents
Low intrinsic carrier density LSMO/Alq3/AlOx/Co organic spintronic devices
2018
The understanding of spin injection and transport in organic spintronic devices is still incomplete, with some experiments showing magnetoresistance and others not detecting it. We have investigated the transport properties of a large number of tris-(8-hydroxyquinoline)aluminum-based organic spintronic devices with an electrical resistance greater than 5 MΩ that did not show magnetoresistance. Their transport properties could be described satisfactorily by known models for organic semiconductors. At high voltages (>2 V), the results followed the model of space charge limited current with a Poole-Frenkel mobility. At low voltages (∼0.1 V), that are those at which t…
Efficacy of a bivalent vaccine against eel diseases caused by Vibrio vulnificus after its administration by four different routes
2003
Vulnivaccine, a vaccine against vibriosis caused by Vibrio vulnificus serovar E (formerly biotype 2), confers acceptable levels of protection to eels after its administration by prolonged immersion in three doses. Recently, a new pathogenic serovar, named serovar A, has been isolated from vaccinated eels in a Spanish freshwater eel farm. The main objective of this work was to design a bivalent vaccine, and to study its effectiveness against the two pathogenic serovars. With this aim, eels weighing around 20 g were immunised with the bivalent vaccine by oral and anal intubation, intraperitoneal injection (i.p.) and prolonged immersion. The overall results indicated that: (i) the new vaccine …
Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring
2017
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …
Retrograde neurotrophic signaling in rat retinal ganglion cells is transmitted via the ERK5 but not the ERK1/2 pathway.
2014
Purpose Neurotrophic deprivation is considered an important event in glaucomatous retinal ganglion cell (RGC) death. However, the mitogen-activated protein kinase (MAPK) pathway transmitting axonal neurotrophic signals in RGC has not been identified. We investigated the involvement of ERK5 and ERK1/2 in retrograde axonal neurotrophic signaling in rats. Methods Adult Sprague-Dawley rats were used. Retinal immunostaining for ERK5 and MEK5 was performed. Levels of total and phosphorylated ERK5 and ERK1/2 were analyzed in retinal lysate by quantitative Western blotting. The effects of age, brain-derived neurotrophic factor (BDNF) stimulation at RGC soma (intravitreal injection) or axon ending (…
Circulating progesterone levels and ongoing pregnancy rates in controlled ovarian stimulation cycles for in vitro fertilization: analysis of over 400…
2010
background: The influence of elevated serum progesterone levels during in vitro fertilization/intracytoplasmic sperm injection (IVF/ ICSI) cycles on pregnancy rates is a matter of continued debate among fertility clinicians. Efforts to resolve this question have been impeded by the various assays used to measure progesterone and the different, arbitrary threshold values for defining ‘high’ progesterone levels. methods: A non-interventional, retrospective, observational, single-centre cohort study evaluated the relationship between serum progesterone levels on the day of human chorionic gonadotrophin (hCG) administration and the ongoing pregnancy rate in 4032 patients undergoing IVF/ICSI cyc…
The heparin-glutathione test: an alternative to the hypo-osmotic swelling test to select viable sperm for intracytoplasmic sperm injection
1998
Abstract Objective: To evaluate the heparin-glutathione test (HEGLUT) for the selection of viable sperm for intracytoplasmic sperm injection (ICSI). Design: A prospective study. Setting: Department of Pediatrics, Obstetrics and Gynecology, University of Valencia and Instituto Valenciano de Infertilidad. Patient(s): Semen samples from healthy donors and patients with infertility. Intervention(s): Sperm samples were kept in culture for different periods in Ham's F-10 medium supplemented or not supplemented with heparin, reduced glutathione (GSH), or a heparin-GSH mixture. Control and heparin-GSH–treated spermatozoa were injected into hamster oocytes. The HEGLUT and ICSI were performed. Main O…
Simultaneous dissolution profiles of two drugs, sulfadiazine-trimethoprim and amitriptyline-perphenazine, in solid oral dosage forms by a FIA manifol…
2002
The simultaneous determination of two dissolution profiles with the aid of a Flow Injection Analysis assembly has been applied to: (a) sulfadiazine-trimethoprim in tablets and (b) amitriptyline-perphenazine in sugar coated pills. The selected combinations are drugs which have overlapping UV-vis spectra. The officially proposed procedure from the pharmacopoeias has been adapted for the FIA methodology and derivative spectrophotometry and zero crossing. Preliminary experiments on the suitability of the simultaneous determination of both drugs were performed. The empirical profiles were adjusted by regression analysis using different approaches. The 3-parameter plot method was finally selected…
Flußquantifizierung von intrakardialen Shuntvolumina unter Verwendung der MR-Phasenkontrast-Technik in Atemanhaltephase
1998
PURPOSE Comparison of a breath-hold, velocity-encoded, phase-difference magnetic resonance (MR) sequence for intracardiac shunt flow measurement with the invasive shunt size determination by oximetry. PATIENTS AND METHODS 10 patients with different cardiac shunts (6 ASD/3 VSD/1 PDA) and four healthy individuals were investigated using a 1.5 Tesla Siemens Vision system. For flow measurements a breath-hold, velocity-encoded, phase-difference magnetic resonance (MR) sequence was used ('through plane', FLASH 2D-sequence, TR/TE 110/5 ms, 'velocity encoding' 250 cm/s). Mean flow (ml/R-R interval) in the ascending aorta, the pulmonary trunk, and the right and left pulmonary arteries was determined…
Importance of spin current generation and detection by spin injection and the spin Hall effect for lateral spin valve performance.
2018
Lateral spin valves are attractive device geometries where functional spin currents can be generated and detected by various mechanisms, such as spin injection and the direct and the inverse spin Hall effect. To understand the mechanisms behind these effects better, as well as their potential for application in devices, we combine multiple mechanisms in multi-terminal Pt-Py-Cu lateral spin valves: we generate pure spin currents in the copper spin conduit both via the spin Hall effect in platinum and electric spin injection from permalloy and detect signals both via conventional non-local detection and via the inverse spin Hall effect in the same device at variable temperatures. Differences …
Polypoidal choroidal vasculopathy in pachychoroid: combined treatment with photodynamic therapy and aflibercept
2022
Abstract Introduction To evaluate the effects of combined therapy using intravitreal Aflibercept (IVA) and photodynamic therapy (PDT) on polypoidal choroidal vasculopathy related to pachychoroid disease (PPCV).Methods Patients with PPCV were treated with PDT combined with 3 IVA injections on a monthly basis, followed by pro re nata criteria. The 12-month follow-up consisted of multiple revaluations of visual acuity and SSOCT parameters of clinical activity.Results Nineteen eyes were included in the study; mean age was 65.5 years. Visual acuity improved after 12 months (0.35 ± 0.25 to 0.2 ± 0.20 logMAR, p = 0.005). Percentage of eyes with intraretinal and subretinal fluid reduced from baseli…